CITS5000       Click for Honeywell Automation Parts

 

 

CITS5000             Excel Plus Microcentral Engineering/Service

 

Class Type            Engineering/Service

 

System                   Microcentral

 

Duration                4.5 Days

 

Class Audience    Mechanical HVAC systems maintenance persons that have responsibility to maintain or  reconfigure Micro/Macrocel systems integrated with their Excel Plus systems using Microcentral/Graphic Central front end. Also, Electrical trades people or Electronic Technicians responsible for Engineering/Reengineering or Servicing an Excel Plus Microcentral HVAC System.

 

Offered At             St Paul or Customer Site

 

# of Students        Minimum 4, Maximum 8

 

Cost                        $2288 per person site, $1483 per person St Paul

 

Brief                      The course provides an overview of the entire Excel Plus system and its extensions and enhancements. The basic portion of the course is a complete discussion of the entire Excel Plus Microcentral Engineering Sequence for any job of any description or complexity.

 

The course is very fast paced and learning takes place in large discrete segments. The course focuses on developing a very independent thought pattern characterized by an aggressive problem-annihilating and not merely problem-solving approach. The course first presents a very detailed block diagram of the Excel Plus Microcentral System. The course then presents a small mechanical system to be controlled by the Excel Plus system. To this end a point file is created quickly to define all mechanical and electrical equipment. This is followed by a Mechanical Systems Data Access scheme that is to be used by the end-user. After this the defined equipment is set in required relationships with each other via the programming language Deltanet Pascal. At this point fire alarm equipment is added to the already created point file.  Fire alarm programs, if any, are also added at this point. 

 

It is also shown that at this point Satellite processors such as Micro/Macrocel point files can be programmed. This completes the data base creation sequence. Each record creation is illustrated on-line using a powerful Honeywell Engineering program. Students follow with the creation of similar records via elaborate written exercises. The created database is then checked via the Validation routines in the engineering program. Error messages are interpreted and errors corrected.

The validated database is then compiled and checked via the Generation Utility of the engineering program. Generation error messages are interpreted and errors corrected.

 

The compiled database is then used to print database logs and reports. These reports are deciphered and interpreted. Their extensive nature and unusually comprehensive nature is noted strongly.

 

The generated database is also used to test operations in Debug mode. This is off-line testing.  The generated database is then used to create media databases for the downline processors and the central processors.

 

The course then goes into media database installation and on-line test and checkout.

 

Finally the entire sequence is done by the students again. This time the students work independently on a given project. A successfully working project is a very satisfying and confidence-building experience.

 

Objectives             Upon completion of the course the student will be able to:

·         Identify Excel Plus Microcentral System Hardware including the Peer Bus and the C-NAP bus

·         Identify software/firmware in all components of the Excel Plus Microcentral Central System

·         Perform all Database Modifications functions using the Interactive Database Modification Utility of the Honeywell Engineering Program

·         Perform the Database Validation Function provided in the Honeywell Engineering

Program

·         Interpret and rectify the validation error messages with dispatch

·         Perform the Database Generation function provided in the Honeywell Engineering

Program

·         Interpret and rectify the Database Generation error messages with dispatch

·         Perform the Media generation functions provided in the Honeywell Engineering Program

·         Generate required reports for analysis

·         Download Generated Databases to the required downline processors

·         Test and Checkout on-line the generated Databases after download

 

Topics                   

·         Excel Plus Microcentral System Block Diagram

·         Overview of Excel Plus System Software/Firmware

·         Nature and significance of R7044 Databases

·         Controller Database Record Access/Display/Modify Procedures Using the Interactive Database Generator of the Engineering Program

·         Database Validation Procedure

·         Validation Error Messages

·         Database Generation/Compilation

·         Database Generation Error Messages

·         Downloading Processor databases

·         Database Test and Checkout

 

CLASS STATISTICS                                                Download Class Description